Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Affix the endcaps on the liner with acetone. It To avoid potential organic contamination of samples, it is important to ensure all sampling on the catwalk has been completed before doing so.
  2. After you have finished processing the CC, measure the length of the final core catcher on the ruler. Give the total length of the core catcher and length of the PAL sample to the Curator or ALO. It is important that this is be an accurate measurement!


Example: For a CC that is 15 cm total length with a 5 cm PAL sample say, "Fifteen with five to PAL" or "Fifteen and five to PAL."

  1. Clean the CC section before handing it off to the core lab. Clean the core catcher bench and tools. Be sure to keep the bench stocked with usable core liner. If running low cut new pieces and stock on shelf below CC bench.

Personal Protective Equipment

Required

Personal protective equipment (PPE) shall include: Hardhathardhat, safety glasses, gloves (work gloves may be preferred because there may be sharp bits on the outer shoe), hearing protection.

Optional

PPE may include: apron or rain coat.
Fig. 1: Extruding core catcher material at the core catcher bench. Notice the Paleontologist waiting with white bowl – give PAL sample to paleontologist.
Image Removed
Image Removed

Fig. 2: Core Catcher Assembly 

(star)Or whatever the length of the PAL sample is.Bottom

Image Removed
Fig. 3: Core catcher material in Core Liner.

Arbor Press


If the Core Catcher material is difficult to manually push out from the core catcher, use the Arbor Press (see Figures 4 and 5). There are two different jigs that can be used to assist with the pushing. One for APC (Figure 6) and one for XCB (one for lower bit; figures 7). Lubricate the moving parts of the arbor press with Lubriplate, or a mixture of Lubriplate and Marvel Mystery Oil.

Figures


Image Added
Fig. 1: Extruding core catcher material at the core catcher bench; notice the Paleontologist waiting with white bowl – give PAL sample to paleontologist.

Image Added

Fig. 2: Core Catcher Assembly 

                  *Or whatever the length of the PAL sample is.


Image Added

Fig. 3: Core catcher material in Core Liner


Image Added 
Fig. 4: Arbor Press.
Image Removed
Image Added 
Fig. 5: Metal disc for pushing on core material.Image Removed 



Image Added
Fig. 6: APC Jig.
Image Removed

Image Added

Fig. 7: XCB bit jig.Image Removed