Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The parts of the stage are detailed below in Figure 4:


 Image RemovedImage Added

Figure 4: Picture of Swift/Hacker Stage with each part detailed.

...

The digital counter connects to the stage via a two slot power cable. The counter is detailed below in Figure 5:

Image Added

Image RemovedFigure 5: The Digital Counter with each part detailed.

...

1.Screw two locating screws into the locations shown below (Figure 6). For installation onto other microscopes you may need to move the locating screws. The Swift sample holder offers several options for different stages.

Image Added

Image RemovedFigure 6: Call outs in red for the locations for locating pins of the back of the Swift/Hacker stag

...

3. Take the screw (Figure 8) and screw into the stage (Figure 9).

Image Added

 Image Removed Figure 8: Screw to secure Swift stage to microscope stage
Image RemovedImage Added
 

Figure 9: User screwing the Swift stage to the microscope stage.

...

  1. Plug the counter into a power source, regulated is preferred.
  2. Take the two-slot power cable from the digital counter and plug into the stage (Figure 10)

Image RemovedImage Added

Figure 10: Two slot power cable from digital counter plugged into stage.

...

  1. Place slide in the holder by sliding the sample in the vertical groove (Figure 11).

Image Added

Image RemovedFigure 11: Slide being placed in the sample holder.

2. Secure the slide by moving the lever arm in so it holds the slide in place (Figure 12).


Image RemovedImage Added

Figure 12: Lever arm securing sample

...

1.Turn the knob counterclockwise to release the gears and allow the holder to slide over to the left (Figure 13). The stage will start to move to left on its own and you should be able to move the stage freely right and left, but it will not stick yet.

Image RemovedImage Added

Figure 13: Knob being turned counterclockwise.

2. Turn the knob clockwise to re-engage the gears. Now the position will not slip to the left anymore and the stage can be pulled to the right to the desired location (Figure 14). A good starting place is to line up the '0' hash mark on the first hash mark of the fixed scale bar, however this will depend on the sample being observed.


Image RemovedImage Added

Figure 14: Rod being pulled to move the horizontal axis back to the right.

...

The position can be set by using either the wheel or the lever, illustrated in Figure 15. The wheel and lever will both move the sample up by 0.2 mm with each click. This step size cannot be altered.
Image RemovedImage Added

Figure 15: Call outs for the location of the wheel and lever.

...

Set the position for the first time using the wheel. The wheel allows for faster and larger adjustments. Turn the wheel towards you, counterclockwise, and the holder will move up (Figure 16).

Image RemovedImage Added

Figure 16: Wheel being turned to move sample up.

To move the holder down or to make larger steps pull the knob at the end of the lever (Figure 17). There is a small pin that typically rests inside a slot. Turn the knob and release so that the pin is outside the slot. The wheel can now be turned freely clockwise or counterclockwise. This is the only way the move the sample down.

Image RemovedImage Added

Figure 17: Knob being pulled out of the lever. The pin is shown by the red callout.

...

The lever is a good way to move the stage in incremented steps while observing the sample. Push down on the lever and then release, the stage will move up in 0.2 mm increments, shown in Figure 18 and Figure 19 below. If the lever does not return all the way, push up on the lever and you will hear the click and observe movement.

Image RemovedImage Added

Figure 18: Lever not depressed.

Image RemovedImage Added

Figure 19: Lever depressed.

...

The gears and gear locations are specific change between the three and four gear setups. The two options are illustrated below in Figure 21 and Figure 22. The circles represent the gear locations and the letter corresponds to the letter stamped on the gear. Note that in both the three and four gear arrangement there are four letters associated with one location. These are all the possible gears that could go in that location.

Image RemovedImage Added

Figure 21: Layout of the three gear combination. The location of Gear A and Gear B are called out. Third gear location could be used with gears C,D,G, or H.

Image RemovedImage Added


Figure 22: Layout of the four gear combination. The location of Gear A, E, and F are called out and fixed. The fourth gear location could be used with gears C, D, G, or H.

...

  1.  Grab a flathead screwdriver and remove the six screws attaching the front plate to the unit (Figure 2223).

Figure 2223: Taking out screw.

2. Pull up the plate by the center knob (Figure 2324).

Figure 2324: Front plate being lifted off.

3. Now you see the inner workings of the stage (Figure 2425). Gears can be lifted out as desired and replaced with a combination listed above. When reattaching the front plate you may need to move the horizontal bar back and forth to get the plate to engage properly with the gears. Do not remove the wheel with the attached paddle. The wheel is connected to a spring and engages with the solenoid.

Image RemovedImage Added

Figure 2425: Stage with front plate removed, revealing the gears and solenoids.

...

Three gear large step (Figure 2526).

Image RemovedImage Added

Figure 2526: Three gear arrangement to produce a 1/3 mm step.

Three gear small step (Figure 2627).


Image RemovedImage Added

Figure 2627: Three gear arrangement to produce a 1/6 mm step.

Four gear large step (Figure

...

28).


Image Added Image Removed
Figure 2728: Four gear arrangement to produce a 1/10 mm step.

Four gear small step (Figure 2829):


Image Added Image Removed
Figure 2829: Four gear arrangement to produce a 1/20mm step.

...